Pressure Profiles of HFRS Vacuum System
-
Graphical Abstract
-
Abstract
HIAF Fragment Separator(HFRS) is connected with Booster Ring(BRing) and Spectrometer Ring (SRing) in the HIAF and used to transfer the ion beams and radioactive secondary beams. To satisfy the requirements of beam transmission and maintain the extremely high vacuum of BRing and SRing, the average pressure of HFRS vacuum system should be lower than 5×10-7 Pa. Therefore, the feasibility of the design scheme and whether the design scheme would fulfill the required vacuum range or not should be verified. Based on the measured data on the current sychrontron CSRm and the simulation results of BOLIDE, the calculation results of VAKTRAK are verified and then VAKTRAK is used to calculate the pressure profiles of different parameters(such as the conductance, out-gassing and pumping speed) for HFRS. According to the calculation results, the average pressure of HFRS vacuum system could be 1.79×10-7(H2) which achieves the required pressure for physics experiments and engineering design. According the calculation results of this paper, the feasibility of the designed HFRS vacuum system has been verified and the design of system satisfies the vacuum requirements.
-
-